Smart Distribution Terminal (TTU)

Description


Functions
 
Electricity measurement function Capable of measuring active energy in both forward and reverse directions
Collection function Capable of measuring reactive energy in both forward and reverse directions, as well as in four quadrants
Equipped with communication sampling function
Meter reading function Collect electricity meter data and remote signal data, including electrical energy, real-time quantity, status quantity, and other intelligent device data (such as voltage monitoring instruments, harmonic meters, etc.)
Real time or scheduled testing of electricity meter data
Storage function It has active reporting function and can transmit data through GPRS/CDMA or SMS communication
Capable of storing real-time call data, load control curve data, 60 day daily data, 12 month monthly data, and nearly 400 alarm events
Abnormal information alarm function Adopting the core technology of "Intelligent Expert Diagnostic System", it has the function of intelligent detection, analysis and automatic alarm of abnormal electricity consumption
Time synchronization function The terminal accepts the timing of the energy meter or the main station, and the timing error does not exceed ± 0.5s
Power outage reporting Proactively report the outage time and current power level when the functional terminal experiences a power outage; After the terminal is powered on, it actively reports the power on time and current battery level
Power outage meter reading function After a power outage, the most recent settled electricity quantity that can read the current electricity quantity can be read
Harmonic monitoring function It can calculate the 21st harmonic content of voltage, the 21st harmonic content of current, and the distortion rate of voltage and current
communication function RS485 communication, infrared communication, GPRS/CDMA communication, Ethernet network communication

Technical Specifications
 
parameter Main technical indicators
Normal operating voltage Rated voltage 3 × 220/380V (± 20%), frequency: 50Hz
Clock accuracy 0.5S/d reference temperature (23 ℃)
Voltage line power consumption ≤ 5W and 10VA (maximum power consumption ≤ 8W in communication state)
working environment Normal operating temperature: -25 ° C to+65 ° C; Extreme operating temperature: -40 ° C to+75 ° C;
Storage and transportation temperature: -40 ℃ to+75 ℃; phase mixing ratio: 10%. 100%
Data transmission interface wireless communication 1-way GPRS/CDMA
Collecting digital energy meters 3-way RS485 interface, communication speed: 300bp5~9600bps
Local communication maintenance 1-way  RS232 interface, communication speed: 1200bps~115200bps: 1 far-infrared, communication speed: 1200bps
spare battery clock battery DC voltage: 3.6V; capacity: ≥ 1200mAh; lifespan: ≥ 15 years
Communication battery DC voltage: 4.8V; Capacity: ≥ 600mAh; Lifespan: ≥ 5 years
Terminal power outage Data will not be lost within 10 years after a power outage, and the power outage terminal will communicate with the main station at least 5 times during its working time
Discrete input 5-way rumor input, 1-way gate node input
precision Active 1.0. Reactive 2.0


 